Friction Tester

The COF-01, COF-01A and FPT-F1 devices measure the static and kinetic coefficient of friction of plastic films, sheets, paper, cardboard, fabrics, rubber and other materials. The PSPT-02 specifically measures the friction of catheters and guide wires in medical technology.
The COF-01 friction coefficient tester is the standard friction tester for every laboratory and is characterized by very high accuracy and is aligned to a total of four standards. For testing the coefficient of friction even at higher temperatures, the COF-01A model is suitable up to temperatures of 90°C.
The FPT-01 is a friction and peel-off tester that can test both static and dynamic coefficient of friction as well at elevated temperatures, as well as peel-off resistance of adhesive materials at 180° peel angle.
The BLD-01 is limited to pull-off resistance but can handle higher forces.
Overview of Testers for Friction and Peeling
Tester | Temperatur | Force Range | Stroke (mm) | Accuracy | Speed | Standards |
---|---|---|---|---|---|---|
COF-01 COF-01A | RT RT – 90°C | 5N opt.10, 30, 50 or 100 N | 300 | 0,05% FS | 100, 150 mm/min | ISO 8295 ASTM D 1894 |
FPT-01 | RT -100°C | 5, 10, 30 N | 300 | 0,1% FS | 0,05-500 mm/min | ASTM D1894, ISO 8295, ISO 8510-2, ASTM D4917 |
PSPT-02 | 0 – 95°C | 10N, opt. 5, 30 or 50 N | 600 | 0,01% FS | 0,05-500 mm/min | ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904 |
BLD-01 | RT | 30, 50, 100, 200 or 500 N | 500 | 0,5% FS | 0,05–1000 mm/min | GB/T 4850-2002 GB 8808 |
Coefficient of Friction Tester

COF-01 / COF-01A
Features:
- Tests the static and kinetic coefficient of friction
- Materials: Plastic foils, rubber, paper, etc.
- Text mode selectable according to standard
- Integrated microcomputer and micro printer
- COF-01A can heat samples up to 90°C
Advantages:
- Standard device with high accuracy
- Temperature range up to 90°C for type COF-01
Force Range | 0 - 5 N, optional 10, 30 , 50 or 100 N |
Accuracy | 0,05% FS |
Stroke | 100, 150 mm |
Speed | 100 mm/min, 150 mm/min |
Standards | ISO 8295, ASTM D1894, TAPPI T816, GB 10006 |

FPT-01
Properties:
- Tests the static and kinetic coefficients of friction of plastic films, sheets, paper, cardboard, fabrics, etc.
- 180° peel test of adhesive materials, such as tape, plaster, foil, etc.
- Variable test speeds
- Complies with several standards
- Computer-controlled
Advantages:
- Wide temperature range up to 100°C
Force Range | 0–5, 0–10 or 0–30 N |
Accuracy | 0,1% FS |
Speed | Variable from 0,05 - 500 mm/min |
Temperature | Room Temperature – 100°C |
Standards | ISO 8295, ISO 8510-2, ASTM D1894, ASTM D4917, ASTM D3330, TAPPI T816, TAPPI T549, GB 10006, GB/T 2790, GB/T 2791, GB/T 2792 |

PSPT-02
Properties:
- Tests the friction and sliding properties of catheters and guidewires
- Temperature adjustment of the water bath
- Vertical arrangement
- Membranes for testing stiffness
- Automatic procedure
- Easy to perform
Advantages:
- Universal tester can be used elsewhere
Force Range | 10 N (Standard; 5, 30 , 50 N (Optional) |
Test Speed | 0,05 – 300 mm/min |
Stroke | 600 mm |
Standards | YY/T 1536-2017, ISO 37, GB 8808, GB/T 1040.1-200, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, QB/T 2358, QB/T 1130 |

BLD-01
Features:
- Peel and strip tests of plastic films, adhesive tapes, paper, cardboard, laminated films, laminating films, fabrics, etc.
- 180° peel-off test of adhesive materials, such as adhesive tape, tape, plaster, laminating film, etc.
- Variable test speeds
Advantages:
- Numerous clamps
Force Range | 30, 50 100, 200 or 500 N |
Sample Width | 30 mm |
Accuracy | 0,5% FS |
Speed | Variable from 0,05 - 1000 mm/min |
Stroke | 500 mm |
Standards | GB/T 4850-2002, GB 8808, GB/T 1040.3-2006, GB/T 17200, GB/T 2790, GB/T 2791, GB/T 2792, QB/T 2358 |
Mobile Hardness Tester

Lpad H100/110/120, Lpad H210
Properties:
- For all steels and aluminium
- All standards such as HL, HV, HRA, HRC, HRB, HB, HS
- Accuracy: 0.5
- Sensor type H100-120: D, DL
- Sensor type H210: D, DL, D+15, DC, C, E, G
- H110-120: Memory for 300 measurements
- H210: USB stick storage
Advantages:
- Good readability with OLED display
- Easy portable pen design
- All data readable at the workstation
Adhesive Tape Roller

YGJ-03
Properties:
- Tests the durability of printing inks on adhesive tapes, plastic films, glass paper and materials printed with gravure printing technology
- Tests the adhesion of the surface layer after vacuum coating and lamination
- Integrated microcomputer
Advantages:
- Standardised test procedure
Roller Pressure | 20 N ±0.5 N |
Speed | 300 mm/min |
Number of Moves | 3 - 999 |
Standards | GB/T 7707, JIS C2107, JIS Z0237 |

IRT-01
Properties:
- Tests of abrasion on printed material like paper, plastic films, packaging etc.
- Fixed tes area
- Automatic procedure
- Counting the number of moves
- Beeps when test is finished
Advantages:
- Easy to use
Force | 20±0.2N |
Test Speed | 0 – 60 cm/min (Standard:43 cpm) |
Test Area | 155 mm x 50 mm |
Stroke | 60 mm |
Number of Moves | 0 - 999999 |
Standards | GB/T 7706 |

HD-M008-2
Features:
- Abrasion Tester for bigger end products like pans, pots, coated material, printed matter etc.
- Different weights possible
- Variable test speed
- Number of strokes are counted
Advantages:
- Unique system for larger products or parts
Force | 21 N |
Test Speed | 6.5 or 33 m/min |
Test Area | 2 x 350 x 350 mm, independent application |
Stroke | 100 mm |
Number of Moves | counted |
Standards | In-house standards |
Needle Tube Tester

MTT-01
Properties:
- Bending properties and strength of medical needle tubes and other materials.
- For normal, thin and ultra-thin tubes
- Load of 20 deflections
- Visual examination of the fracture behaviour
Advantages:
- Easy to perform
Bending Angle | 15°, 20°, 25° |
Needle Tube Diameter | 0,2 – 3,4 mm |
Load Frequency | 0,5 Hz |
Standards | GB/T 18457-2015, ISO9626-1991, GB/T 15811-2016 |

MRT-01
Properties:
- Tests the stiffness of medical needles
- For normal, thin and ultra-thin needles
- Automatic calibration
Advantages:
- Simple test procedure
Deflection | 0 – 5 mm |
Deflection Force | 0 – 80 N |
Deflection Speed | 0 – 10 mm/min |
Needle Diameter | 0,3 – 3,4 mm |
Standards | GB 15811, YBB00092004-2015, GB 18457 |